Rt®-Alumina BOND/KCl Columns(熔融石英plot柱)

更新时间:  2017-07-09

产品型号:  

产品报价:  

所  在  地:  北京市朝阳区望京西园222号星源国际D座1503室

产品特点:  The Rt?-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored.

(联系我们,请说明是在 北京明尼克分析仪器设备中心 上看到的信息,谢谢!)

产品概述

Rt®-Alumina BOND/KCl Columns (fused silica PLOT)

(KCl deactivation)

Guaranteed Reproducibility
Each Rt
®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene.
With our new technology, both Na
2SO4 and KCl are available with the Rt®-Alumina BOND columns.

Similar Phase(s):

GC-Alumina KCl, CP-Al2O3/KCl

catalog #

length

id

df

units

 

19761

30m

0.32mm

5μm

ea.

19762

50m

0.32mm

5μm

ea.

19759

30m

0.53mm

10μm

ea.

19760

50m

0.53mm

10μm

ea.

Showing 1 to 4 of 4 entries

 

1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored. 5. High capacity and loadability give exceptionally symmetric peaks; ideal for volatile hydrocarbon separations at percent levels, as well as impurity analyses at ppm concentrations.

Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.

*       Acetylene elutes before C4 hydrocarbons (impurities in butane/isobutane).

*       Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene.

 

 

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7
北京明尼克分析仪器设备中心

北京明尼克分析仪器设备中心

联系人:薛海玲  电话:010-84723211  邮箱:xuehail@163.com  总部地址:北京市朝阳区望京西园222号星源国际D座1503室

研发中心:北京市平谷区中关村科技园区兴谷A区平和街39号院(联东U谷)22号楼C区

版权所有 © 2024 北京明尼克分析仪器设备中心  总流量:954265  备案号:京ICP备10037012号-2

管理登陆  网站地图  技术支持:化工仪器网